Inhibition of Intrinsic Thrombin Generation

Submit a Paper



Publication Date: 23 Oct 2006

Journal: Drug Target Insights

Citation: Drug Target Insights 2006:1 5-10

Abstract

Background: The contact phase of coagulation is of physiologic/pathophysiologic importance, whenever unphysiologic polynegative substances such as cell fragments (microparticles) get in contact with blood. There are several clinically used inhibitors of intrinsic thrombin generation. Here the inhibitory concentrations 50% (IC50) of these anticoagulants are measured by the highly specifi c thrombin generation assay INCA.

Methods: Unfrozen pooled normal citrated plasma in polystyrole tubes was supplemented at 23°C in duplicate with 0–2 IU/ml low molecular weight heparin (dalteparin), 0–2 IU/ml unfractionated heparin, 0–500 KIU/ml aprotinin, or 0–40 mM arginine. 50 μl plasma or 1 IU/ml thrombin standard were pipetted into a polystyrole microtiter plate with fl at bottom. 5 μl SiO2/ CaCl2 - reagent (INCA activator) were added and after 0–30 min incubation at 37°C 100 μl 2.5 M arginine, pH 8.6, were added; arginine inhibits hemostasis activation and depolymerizes generated fi brin within 20 min at 23°C. The in the physiologic 37°C incubation phase generated thrombin was then chromogenically detected. The intra-assay CV values were < 5%.

Results and Discussion: The approximate IC50 were 0.01 IU/ml dalteparin, 0.02 IU/ml heparin, 25 KIU/ml aprotinin, and 12 mM arginine. The effi ciency of any anticoagulant on intrinsic thrombin generation should be measured for each individual patient.

Abbreviations: IIa, thrombin; ΔA, increase in absorbance; APTT, activated partial thromboplastin time; CRT, coagulation reaction time (at 37°C in water-bath); F-wells, polystyrole microtiter plates with fl at bottom; IC50, inhibitory concentration 50%; INCA, intrinsic coagulation activity assay; IU, international units; KIU, kallikrein inhibiting unis; LMWH, low molecular weight heparin; mA, milli-absorbance units; PSL, pathromtin SL®; RT, room temperature (23°C); U-wells, polystyrole microtiter plates with round bottom.


Downloads

PDF  (1.11 MB PDF FORMAT)

RIS citation   (ENDNOTE, REFERENCE MANAGER, PROCITE, REFWORKS)

BibTex citation   (BIBDESK, LATEX)

XML

PMC HTML


Sharing

Our Service Promise

  • Prompt Processing (Less Than 3 Weeks)
  • Fair & Comprehensive Peer Review
  • Professional Author Service
  • Leading Editors in Chief
  • Extensive Indexing
  • High Readership & Impact
  • What Your Colleagues Say

Quick Links

Follow Us We make it easy to find new research papers.
Email AlertsRSS Feeds
FacebookGoogle+Twitter
PinterestTumblrYouTube

SUBJECT HUBS
Our Testimonials
Publishing in Air, Soil and Water and Water Research was the best experience I have had so far in an academic context.  The review process was fair, quick and efficient.  I congratulate the team at Libertas Academica for a very well managed journal.
Magnus Karlsson (IVL Swedish Environmental Research Institute, Stockholm, Sweden) What Your Colleagues Say