Abstract:

Background: We have recently developed a new technique for quantitatively measuring protein-bound 3-nitrotyrosine (3-NT), a footprint of nitrosative stress, utilizing high-performance liquid chromatography with an electrochemical detection (HPLC-ECD) system. Using this system, we showed that 3-NT formation was upregulated in the sputum of both COPD and asthmatic patients. However, in order to improve the accuracy of the measurement system. We have to resolve some problems which were the influence of free amino acid form of 3-NT and of salivary contamination.

Objectives: We initially investigated the amount of the free amino acid form of 3-NT in induced sputum and compared with that of protein-bound 3-NT. Next, we evaluated the concentration of protein-bound 3-NT in saliva and compared with that in induced sputum by means of HPLC-ECD.

Methods: Five male COPD patients were enrolled. Induced sputum and saliva were obtained from the patients. The free amino acid form of 3-NT in sputum and saliva was measured by HPLC-ECD, and the protein-bound 3-NT and tyrosine in sputum and saliva were enzymatically hydrolyzed by Streptomyces griseus Pronase and measured for the protein hydrolysate by HPLC-ECD.

Results: The mean value of the amount of protein-bound 3-NT was 65.0 fmol (31.2 to 106.4 fmol). On the other hand, the amount of the free amino acid form of 3-NT was under the detection limit (<10 fmol). The levels of both 3-NT (sputum: 0.55 ± 0.15 pmol/ml, saliva: 0.02 ± 0.01 pmol/ml, p < 0.01) and tyrosine (sputum: 0.81 ± 0.43 μmol/ml, saliva: 0.07 ± 0.04 μmol/ml, p < 0.01) in saliva were significantly lower than in sputum. The percentage of 3-NT in saliva to that in sputum was about 3.1%, and that of tyrosine was about 9.0%.

Conclusion: The free amino acid form of 3-NT does not affect the measurement of protein-bound 3-NT. Furthermore, the influence of salivary contamination on the measurement of protein-bound 3-NT in induced sputum by means of HPLC-ECD
was very small and could be negligible.


Post a Comment

x close

Discussion Add A Comment
No comments yet...Be the first to comment.


share on

Our Service Promise

  • Prompt Processing (Less Than 3 Weeks)
  • Fair & Comprehensive Peer Review
  • Professional Author Service
  • Leading Editors in Chief
  • Extensive Indexing
  • High Readership & Impact
  • What Our Authors Say

Quick Links

Follow Us We make it easy to find new research papers. RSS Feeds Email Alerts Twitter

BROWSE CATEGORIES
Our Testimonials
As the Editor-in-Chief of Clinical Medicine Insights: Reproductive Health, I experience outstanding professional and friendly assistance by the publisher, Libertas Academica, in all editorial matters.
Zeev Blumenfeld (Rappaport Institute, Technion, Faculty of Medicine, Haifa, Israel) What our authors say