Posted Wed, Apr, 23,2014

Published today in Analytical Chemistry Insights is a new original research article by Okechukwu Clinton Ifegwu, Chimezie Anyakora, Samuel Chigome and Nelson Torto.  Read more about this paper below:

Title

Application of Nanofiber-packed SPE for Determination of Urinary 1-Hydroxypyrene Level Using HPLC

Abstract

It is always desirable to achieve maximum sample clean-up, extraction, and pre-concentration with the minimum possible organic solvent. The miniaturization of sample preparation devices was successfully demonstrated by packing 10 mg of 11 electrospun polymer nanofibers into pipette tip micro column and mini disc cartridges for efficient pre-concentration of 1-hydroxypyrene in urine samples. 1-hydroxypyrene is an extensively studied biomarker of the largest class of chemical carcinogens. Excretory 1-hydroxypyrene was monitored with HPLC/fluorescence detector. Important parameters influencing the percentage recovery such as fiber diameter, fiber packing amount, eluent, fiber packing format, eluent volume, surface area, porosity, and breakthrough parameters were thoroughly studied and optimized. Under optimized condition, there was a near perfect linearity of response in the range of 1–1000 µg/L with a coefficient of determination (r²) between 0.9992 and 0.9999 and precision (% RSD) ≤7.64% (n = 6) for all the analysis (10, 25, and 50 µg/L). The Limit of detection (LOD) was between 0.022 and 0.15 µg/L. When compared to the batch studies, both disc packed nanofiber sorbents and pipette tip packed sorbents exhibited evident dominance based on their efficiencies. The experimental results showed comparable absolute recoveries for the mini disc packed fibers (84% for Nylon 6) and micro columns (80% for Nylon 6), although the disc displayed slightly higher recoveries possibly due to the exposure of the analyte to a larger reacting surface. The results also showed highly comparative extraction efficiencies between the nanofibers and conventional C-18 SPE sorbent. Nevertheless, miniaturized SPE devices simplified sample preparation, reducing back pressure, time of the analysis with acceptable reliability, selectivity, detection levels, and environmental friendliness, hence promoting green chemistry.

Click here to learn more about the article, download it and comment

share on

Posted in: Articles Published

  • Efficient Processing: 4 Weeks Average to First Editorial Decision
  • Fair & Independent Expert Peer Review
  • High Visibility & Extensive Database Coverage
Services for Authors
What Your Colleagues Say About Libertas Academica
testimonial_image
As an open access journal with an international audience, Air, Soil and Water Research has a tremendous worldwide impact.  Peer reviewing process is essential to maintain the high standard of quality of published papers, and I have thoroughly enjoyed my participation as a reviewer for Air, Soil and Water Research. The online review system is very easy and simply to use. I am looking forward to peer reviewing additional articles in the future. ...
Dr Dionisis Gasparatos (Agricultural University of Athens, Athens, Greece)
More Testimonials

Quick Links


New article and journal news notification services
Email Alerts RSS Feeds
Facebook Google+ Twitter
Pinterest Tumblr YouTube