Close
Help


Aphakia Correction by Foldable Anterior Chamber Lens

Posted Mon, Dec, 02,2013

Published today in Ophthalmology and Eye Diseases is a new original research article by Kagmeni Giles, Moukouri Ernest, Domngang Christelle, Nguefack-Tsague Georges, Cheuteu Raoul, Ebana Mvogo Come and Peter Wiedemann.  Read more about this paper below:

Title

Aphakia Correction by Injection of Foldable Intra Ocular Lens in The Anterior Chamber

Abstract

We assessed the outcomes of the use of anterior chamber foldable lens for unilateral aphakia correction at the University Teaching Hospital of Yaounde. In this retrospective, non-comparative, consecutive case series study, we reviewed the records of patients who underwent an operation for aphakia correction by the means of injection of an angular supported foldable lens between January 2009 and December 2011 in the University Teaching Hospital Yaounde. Student’s paired t-test was carried out to compare pre-operative and post-operative visual acuity (VA) and intraocular pressure (IOP). P-values less than 0.05 were considered statistically -significant. Twenty-one patients were included in the study; twelve were male (57.1%) and nine were female (42.9%). The mean age was 55.38 ± 17.67 years (range 9–75 years). The mean follow-up duration was 5.95 ± 3.14 months (range 2–12 months). The mean logMAR visual acuity was 1.26 ± 0.46 pre-operatively and 0.78 ± 0.57 post-operatively (P ± 0.003). The change in intraocular pressure was not statistically significant. Complications included intraocular hypertension (over 21 mmHg) in 3 patients (14.3%) and macular edema, pupillar ovalization, and retinal detachment in one patient each. The results indicate that injection of an angular support foldable lens in the anterior chamber is a useful technique for the correction of aphakia in eyes without capsular support. More extended follow-up, however, and a larger series of patients are needed to ascertain the effectiveness and safety of this procedure.

Click here to learn more about the article, download it and comment

share on

Posted in: Articles Published

  • Efficient Processing: 4 Weeks Average to First Editorial Decision
  • Fair & Independent Expert Peer Review
  • High Visibility & Extensive Database Coverage
Services for Authors
What Your Colleagues Say About Libertas Academica
As a peer reviewer for Environmental Health Insights, I have had the opportunity to read several very important research articles in my field.  Based on my experience, the submission process, review standards, and publication expectations are rigorous and demanding as other high impact journals.  I look forward to further reviewing papers for Environmental Health Insights and learning from my peers and other leaders in the field.
Dr Jianbo Jiang (Monell Chemical Senses Center, Philadelphia, PA, USA)
More Testimonials

Quick Links


New article and journal news notification services
Email Alerts RSS Feeds
Facebook Google+ Twitter
Pinterest Tumblr YouTube