Solid Phase Extraction for Monitoring of Occupational Exposure to Cr (III)
S.J. Shahtaheri1, M. Khadem1, F. Golbabaei1 and A. Rahimi-Froushani2
1Department of Occupational Health, Tehran University of Medical Sciences, Iran. 2Department of Epidemiology and Biostatistics, Tehran University of Medical Sciences, Iran.
Abstract: Chromium is an important constituent widely used in different industrial processes for production of various synthetic materials. For evaluation of workers’ exposure to trace toxic metal of Cr (III), environmental and biological monitoring are essential processes, in which, preparation of samples is one of the most time-consuming and error-prone aspects prior to analysis. The use of solid-phase extraction (SPE) has grown and is a fertile technique of sample preparation as it provides better results than those produced by liquid-liquid extraction (LLE). SPE using mini columns filled with XAD-4 resin was optimized regarding to sample pH, ligand concentration, loading flow rate, elution solvent, sample volume, elution volume, amount of resins, and sample matrix interferences. Chromium was retained on solid sorbent and was eluted with 2 M HNO3 followed by simple determination of analytes by using flame atomic absorption spectrometery. Obtained recoveries of metal ion were more than 92%. The optimized procedure was also validated with three different pools of spiked urine samples and showed a good reproducibility over six consecutive days as well as six within-day experiments. Through this study, suitable results were obtained for relative standard deviation, therefore, it is concluded that, this optimized method can be considered to be successful in simplifying sample preparation for trace residue analysis of Cr in different matrices for evaluation of occupational and environmental exposures. To evaluate occupational exposure to chromium, 16 urine samples were taken, prepared, and analyzed based on optimized procedure.
Readers of this also read:
- Solid-Phase Extraction and Reverse-Phase HPLC: Application to Study the Urinary Excretion Pattern of Benzophenone-3 and its Metabolite 2,4-Dihydroxybenzophenone in Human Urine
- Quantitative Mass spectrometric Analysis of Ropivacaine and Bupivacaine in Authentic, Pharmaceutical and Spiked Human Plasma without Chromatographic Separation
- High-Performance Liquid Chromatographic Method for Determination of Phenytoin in Rabbits Receiving Sildenafil
- Uncertainty Analysis of Drug Concentration in Pharmaceutical Mixtures
- New Spectrofluorimetric Method with Enhanced Sensitivity for Determination of Paroxetine in Dosage Forms and Plasma